超純氫中痕量O_2+Ar、N_2、CO、CH_4和CO_2測定
超純氫中痕量O_2+Ar、N_2、CO、CH_4和CO_2測定 詳細(xì)信息:


浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司用氣相色譜法測定了超純氫中痕量雜質(zhì)O_2+Ar、N_2、CO、CH_4和CO_2。將TCD和FID與預(yù)濃縮技術(shù)結(jié)合,當(dāng)濃縮樣品量為10升時,檢測靈敏度分別達(dá)到O_2+Ar為0.2ppbV、N_2為0.4ppbV、CO為0.05ppbV、CH_4為0.2ppbV和CO_2為0.3ppbV。提出用濃縮體積差值法和按峰面積法兩種方法計算樣品中雜質(zhì)濃度,前一種方法可消除載氣中雜質(zhì)濃度的影響。



名稱:MS5?填充柱
規(guī)格:1m*1/8,60-80Mesh
*高使用溫度:300°C
編號:20221207007
應(yīng)用:氫,氧,氮,甲烷,一氧化碳的分離

名稱:填充柱

型號:GDX-104

規(guī)格:3m*4mm,60-80目

*高溫度:250°C





浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司,研究了氧氣對空氣中甲烷、總烴分析時的干擾.得出,載氣的純度很高時使用GDX-502填充柱可以將甲烷峰和氧峰完全分離,甲烷和總烴和分析可不受氧峰干擾,氣樣中氧氣濃度低于17%時氧峰可忽略,低于12.5%時氧峰消失.氫火焰離子化檢測器不能檢出氧氣,氧峰僅為干擾峰,在一定的色譜條件下,干擾峰即氧峰和氣樣中的氧氣濃度成正比關(guān)系.當(dāng)氣樣中氧氣濃度小于28.7%時,總烴值峰值等于甲烷測試時氧峰和各烴峰之和,當(dāng)氧氣濃度大于28.7%時,不能用國標(biāo)氣相色譜法測試總烴,總烴值應(yīng)等于總烴峰值值減去該氣樣的氧值.



超純氫中痕量O_2+Ar、N_2、CO、CH_4和CO_2測定測試譜圖:



Trace O in ultrapure hydrogen_ 2+Ar、N_ 2、CO、CH_ 4 and CO_ 2 Determination

Trace O in ultrapure hydrogen_ 2+Ar、N_ 2、CO、CH_ 4 and CO_ 2 Determination details:




The trace impurity O in ultrapure hydrogen was determined by gas chromatography in Haohan Chromatography (Shandong) Application Technology Development Co., Ltd_ 2+Ar、N_ 2、CO、CH_ 4 and CO_ 2。 Combining TCD and FID with pre concentration technology, when the concentration sample volume is 10 liters, the detection sensitivity reaches O respectively_ 2+Ar is 0.2ppbV, N_ 2 is 0.4ppbV, CO is 0.05ppbV, CH_ 4 is 0.2ppbV and CO_ 2 is 0.3ppbV. Two methods, concentration volume difference method and peak area method, are proposed to calculate the impurity concentration in the sample. The former method can eliminate the influence of the impurity concentration in the carrier gas.





Name: MS5A packed column

Specification: 1m * 1/8, 60-80Mesh

*High service temperature: 300 ° C

No.: 20221207007

Application: separation of hydrogen, oxygen, nitrogen, methane and carbon monoxide

Name: Filled column



Model: GDX-104



Specification: 3m * 4mm, 60-80 meshes



*High temperature: 250 ° C










The interference of oxygen on the analysis of methane and total hydrocarbons in air was studied by Haohan Chromatography (Shandong) Application Technology Development Co., Ltd It is concluded that when the purity of the carrier gas is very high, the use of GDX-502 packed column can completely separate the methane peak and the oxygen peak. The methane and total hydrocarbons and analysis can not be interfered by the oxygen peak. When the oxygen concentration in the gas sample is lower than 17%, the oxygen peak can be ignored, and when it is lower than 12.5%, the oxygen peak disappears The hydrogen flame ionization detector cannot detect oxygen, and the oxygen peak is only an interference peak. Under certain chromatographic conditions, the interference peak, that is, the oxygen peak, is proportional to the oxygen concentration in the gas sample. When the oxygen concentration in the gas sample is less than 28.7%, the total hydrocarbon value peak is equal to the sum of the oxygen peak and each hydrocarbon peak in the methane test. When the oxygen concentration is greater than 28.7%, the total hydrocarbon cannot be tested by the national standard gas chromatography. The total hydrocarbon value should be equal to the total hydrocarbon peak value minus the oxygen value of the gas sample





Trace O in ultrapure hydrogen_ 2+Ar、N_ 2、CO、CH_ 4 and CO_ 2 Determination of test spectrum:


相關(guān)產(chǎn)品

20%OV-101/Gas Chrom Q,, 水果中二硫代氨基甲酸酯殘留檢驗
水果中二硫代氨基甲酸酯殘留檢驗賽默飛玻璃柱,非甲烷總烴,液化石油氣,頂空進(jìn)樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
GDX-102,, 化妝品中甲醇測定測定填充柱應(yīng)用安捷倫7890
化妝品中甲醇測定測定填充柱應(yīng)用安捷倫7890,非甲烷總烴,液化石油氣,頂空進(jìn)樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
1m*3mm,, TDX-01填充柱應(yīng)用在安捷倫/島津/賽默飛
TDX-01填充柱應(yīng)用在安捷倫/島津/賽默飛,島津,非甲烷總烴,液化石油氣,頂空進(jìn)樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
HH-silica gel,, 硅膠填充柱應(yīng)用島津GC2014測定甲烷乙烯乙
硅膠填充柱應(yīng)用島津GC2014測定甲烷乙烯乙烷,島津,非甲烷總烴,液化石油氣,頂空進(jìn)樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
1M*1/8,, MS5?甲烷柱應(yīng)用賽默飛1300測定空氣中CH4
MS5?甲烷柱應(yīng)用賽默飛1300測定空氣中CH4,島津,非甲烷總烴,液化石油氣,頂空進(jìn)樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
HH-C1-5 快速色譜專用柱分析C1-C5的烴應(yīng)用安捷倫7890
快速色譜專用柱分析C1-C5的烴應(yīng)用安捷倫7890,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦?fàn)t煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑,消毒劑,氨水