HH-PLOT-Molecular sieve-II甲烷毛細(xì)管 大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析
產(chǎn)品名稱:HH-PLOT-Molecular sieve-II甲烷毛細(xì)管 大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析
產(chǎn)品型號(hào):HH-PLOT-Molecular sieve-II甲烷毛細(xì)管
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司
簡(jiǎn)單介紹
大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析,口罩,增塑劑,塑化劑,消毒劑,氨水,氨氣,乙酸乙酯,醫(yī)療器械,環(huán)氧乙烷,增塑劑,過(guò)氧化物,氨氣,二甲醚 ,MTBE,頂空進(jìn)樣器,EO
HH-PLOT-Molecular sieve-II甲烷毛細(xì)管 大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析的詳細(xì)介紹
大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析
大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析 詳細(xì)信息:
大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析 測(cè)試譜圖:







Mo nitoring and Analysis of Methane, Total Hydrocarbons and Non-Methane Total Hydrocarbons in Atmosphere
Mo nitoring and analysis of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere Details:
Methane capillary column:
Statio nary phase: Porous layer open tube molecular sieve column or other equivalent capillary column
Specifications: 30m*0.53mm*25um
Model: HH-PLOT-Molecular sieve-II
Application: HJ 38-2017 Waste gas from statio nary pollution sources-Determination of total hydrocarbons, methane and non-methane total hydrocarbons-Gas chromatography
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. adopts six-port valve injection, dual capillary column, dual FID detector gas chromatography, and can measure CH4, total hydrocarbons and non-methane total hydrocarbons (NMHC) in the atmosphere with one injection. ) test data. At the same time, the oxygen peak in the FID detector in the chromatogram can be initially identified as "interference peak", which can be ignored in the analysis. The detection limit of the method: CH4 0.03mg/m3, total hydrocarbons 0.04mg/ m3, NMHC0.06mg/m3. Variation coefficient: CH4 3.81%, total hydrocarbons 2.07%, NHMC 5.07%. Standard recovery: CH4 96.1%, NHMC 96.1%~98%.
Mo nitoring and analysis of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere Test spectrum:
大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析 詳細(xì)信息:
甲烷毛細(xì)管柱:
固定相:多孔層開(kāi)口管分子篩柱或其他等效毛細(xì)管柱
規(guī)格:30m*0.53mm*25um
型號(hào):HH-PLOT-Molecular sieve-II
應(yīng)用:HJ 38-2017 固定污染源廢氣 總烴、甲烷和非甲烷總烴的測(cè)定 氣相色譜法
浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司采用六通閥進(jìn)樣,雙毛細(xì)管柱,雙FID檢測(cè)器氣相色譜法,一次進(jìn)樣即可測(cè)得大氣中的CH4,總烴及非甲烷總烴(NMHC)的測(cè)試數(shù)據(jù).同時(shí)對(duì)色譜中FID檢測(cè)器中出現(xiàn)的氧峰初步可認(rèn)定為"干擾峰",在分析中可忽略不計(jì).方法的檢出限:CH4 0.03mg/m3,總烴0.04mg/m3,NMHC0.06mg/m3.變異系數(shù):CH4 3.81%,總烴2.07%,NHMC5.07%.加標(biāo)回收率:CH4 96.1%,NHMC96.1%~98%.大氣中甲烷、總烴及非甲烷總烴監(jiān)測(cè)分析 測(cè)試譜圖:







Mo
Mo
Methane capillary column:
Statio
Specifications: 30m*0.53mm*25um
Model: HH-PLOT-Molecular sieve-II
Application: HJ 38-2017 Waste gas from statio
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. adopts six-port valve injection, dual capillary column, dual FID detector gas chromatography, and can measure CH4, total hydrocarbons and non-methane total hydrocarbons (NMHC) in the atmosphere with one injection. ) test data. At the same time, the oxygen peak in the FID detector in the chromatogram can be initially identified as "interference peak", which can be ignored in the analysis. The detection limit of the method: CH4 0.03mg/m3, total hydrocarbons 0.04mg/ m3, NMHC0.06mg/m3. Variation coefficient: CH4 3.81%, total hydrocarbons 2.07%, NHMC 5.07%. Standard recovery: CH4 96.1%, NHMC 96.1%~98%.