5%PEG-6000/6201(60-80目)填充柱 GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜
您所在的位置:首頁 > 產(chǎn)品展示 > 填充柱

5%PEG-6000/6201(60-80目)填充柱 GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜

如果你感興趣的話,可以電話:0632-5667636

產(chǎn)品名稱:5%PEG-6000/6201(60-80目)填充柱 GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜

產(chǎn)品型號(hào):5%PEG-6000/6201(60-80目)填充柱

產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司

簡單介紹

GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦?fàn)t煤氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑,消毒劑

5%PEG-6000/6201(60-80目)填充柱 GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜的詳細(xì)介紹

GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜
GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜 詳細(xì)信息:

名稱:填充柱

固定液:5%聚乙二醇6000
規(guī)格:2m*4mm
型號(hào):5%PEG-20M/6201(60-80目)
應(yīng)用:GB/T 16052-1995車間空氣中苯乙烯的直接進(jìn)樣氣相色譜測定方法

浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司建立了直接進(jìn)樣測定工業(yè)廢氣中苯乙烯的氣相色譜法。工業(yè)廢氣樣品通過氣體進(jìn)樣閥進(jìn)入氣相色譜儀中進(jìn)行分離和檢測,采用0.25 mL氣體進(jìn)樣閥時(shí),方法的檢出限為1.4 mg/m3,苯乙烯含量在3.19~51.0 mg/m3時(shí),測定結(jié)果的相對(duì)標(biāo)準(zhǔn)偏差為2.19%~4.50%(n=5),與行業(yè)標(biāo)準(zhǔn)HJ 583-2010,HJ 584-2010相比,該方法操作簡便、快速,適合工業(yè)廢氣中苯乙烯的快速測定。

GB/T 16052-1995 車間空氣中苯乙烯的直接進(jìn)樣氣相色譜  測試譜圖:




GB/T 16052-1995 Direct injection gas chromatography of styrene in workshop air
GB/T 16052-1995 Direct injection gas chromatography of styrene in workshop air Details:

Name: Packed Column

Fixative: 5% polyethylene glycol 6000
Specifications: 2m*4mm
Model: 5%PEG-20M/6201 (60-80 mesh)
Application: GB/T 16052-1995 Method for Determination of Styrene in Workshop Air by Direct Injection Gas Chromatography

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has established a gas chromatography method for the determination of styrene in industrial waste gas by direct injection. The industrial waste gas samples entered the gas chromatograph through the gas injection valve for separation and detection. When the 0.25 mL gas injection valve was used, the detection limit of the method was 1.4 mg/m3, and when the styrene content was 3.19-51.0 mg/m3, The relative standard deviation of the determination results was 2.19%-4.50% (n=5). Compared with the industry standards HJ 583-2010 and HJ 584-2010, the method was simple and fast, and was suitable for the rapid determination of styrene in industrial waste gas.

GB/T 16052-1995 Direct injection gas chromatographic test spectrum of styrene in workshop air:

相關(guān)產(chǎn)品

HH-CO2-CH4-N2O,, 二氧化碳、甲烷和氧化亞氮的大氣水平測
二氧化碳、甲烷和氧化亞氮的大氣水平測定專用毛細(xì)管柱,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三
HH-Methanol III,, CO_2加氫合成甲醇檢測專用填充柱安裝在
CO_2加氫合成甲醇檢測專用填充柱安裝在安捷倫,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙
2m*3mm,, 熱導(dǎo)檢測器使用的平衡柱安裝在安捷倫8890上
熱導(dǎo)檢測器使用的平衡柱安裝在安捷倫8890上,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺
2m*3mm,, 餐具洗滌劑中1,4-二噁烷GDX-103柱測定
餐具洗滌劑中1,4-二噁烷GDX-103柱測定,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺,氨
5g 氯化氫檢測專用色譜填料80-100mesh
氯化氫檢測專用色譜填料80-100mesh,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺,氨
25g,,, DC-200色譜固定液
DC-200色譜固定液,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺,氨