在线观看亚洲av无码专区_97超开公碰在线视频_单身在线观看3级无码_97超碰高清中文版

15562228838(微信同號)13963221227(微信同號)
聚乙二醇-20M 空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱
您所在的位置:首頁 > 產(chǎn)品展示 > 填充柱

聚乙二醇-20M 空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱

如果你感興趣的話,可以電話:0632-5667636

產(chǎn)品名稱:聚乙二醇-20M 空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱

產(chǎn)品型號:聚乙二醇-20M

產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司

簡單介紹

空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,焦?fàn)t煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑,過氧化物,乙酸乙酯,頂空

聚乙二醇-20M 空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱的詳細(xì)介紹

空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱
空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱 詳細(xì)信息:

名稱:毛細(xì)管柱

固定液:聚乙二醇-20M

規(guī)格:30m*0.32mm*0.25um

型號:PEG-20M
應(yīng)用:  空氣中環(huán)氧氯丙烷的新測定

浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司建立一種測定空氣中環(huán)氧氯丙烷的新方法。方法:空氣中的環(huán)氧氯丙烷用活性碳管采集,熱解吸后,經(jīng)PEG-20M柱分離,氫焰離子化檢測器檢測,對色譜柱,色譜條件,采集條件,熱解吸條件等進(jìn)行優(yōu)選。結(jié)果:方法的檢測限為0.001μg/m l,低檢出濃度為0.03 mg/m3(采樣體積3 L)。當(dāng)標(biāo)準(zhǔn)溶液濃度為0.002、0.004、0.010μg/m l時,平均相對標(biāo)準(zhǔn)偏差為5.0%、4.8%、1.2%,標(biāo)準(zhǔn)曲線的相關(guān)系數(shù)為0.9999。平均解吸效率為97.1%,采樣效率為95%,穿透容量大于1.4 mg。樣品在采樣管中可穩(wěn)定7 d以上。結(jié)論:通過樣品測試證明,該法采用活性碳管采樣,攜帶方便,采樣代表性好,樣品穩(wěn)定時間長;采樣后解吸效率高;所選用的色譜柱具有柱效高,分離度好,色譜峰形好的優(yōu)點。本法適用于現(xiàn)場監(jiān)測和個體采樣。


空氣中環(huán)氧氯丙烷的新測定毛細(xì)管柱  測試譜圖:



A new capillary column for the determination of epichlorohydrin in air
New capillary column for the determination of epichlorohydrin in air Details:

Name: capillary column

Fixative: polyethylene glycol-20M

Specifications: 30m*0.32mm*0.25um

Model: PEG-20M
Application: New determination of epichlorohydrin in air

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. established a new method for the determination of epichlorohydrin in air. Methods: The epichlorohydrin in the air was collected by activated carbon tube, and after thermal desorption, it was separated by PEG-20M column and detected by hydrogen flame ionization detector. Make optimization. Results: The detection limit of the method was 0.001 μg/m l, and the minimum detection concentration was 0.03 mg/m3 (sampling volume was 3 L). When the concentration of the standard solution was 0.002, 0.004 and 0.010 μg/ml, the average relative standard deviations were 5.0%, 4.8% and 1.2%, and the correlation coefficient of the standard curve was 0.9999. The average desorption efficiency was 97.1%, the sampling efficiency was 95%, and the penetration capacity was greater than 1.4 mg. The sample can be stable for more than 7 days in the sampling tube. Conclusion: It is proved by sample test that the method adopts activated carbon tube for sampling, which is convenient to carry, has good sampling representative, and has a long sample stability time; the desorption efficiency after sampling is high; the selected chromatographic column has high column efficiency, good resolution, and chromatographic peak good form. This law applies to on-site monitoring and individual sampling.


Test chromatogram of a new capillary column for the determination of epichlorohydrin in air:

相關(guān)產(chǎn)品

HH-Methanol III,, CO_2加氫合成甲醇檢測專用填充柱安裝在
CO_2加氫合成甲醇檢測專用填充柱安裝在安捷倫,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙
2m*3mm,, 熱導(dǎo)檢測器使用的平衡柱安裝在安捷倫8890上
熱導(dǎo)檢測器使用的平衡柱安裝在安捷倫8890上,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺
2m*3mm,, 餐具洗滌劑中1,4-二噁烷GDX-103柱測定
餐具洗滌劑中1,4-二噁烷GDX-103柱測定,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺,氨
5g 氯化氫檢測專用色譜填料80-100mesh
氯化氫檢測專用色譜填料80-100mesh,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺,氨
25g,,, DC-200色譜固定液
DC-200色譜固定液,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺,氨
5%Carbowax20M Carbopack B 固定污染源廢氣中的甲醇測定石
固定污染源廢氣中的甲醇測定石墨化碳黑柱,安捷倫,安捷倫,賽默飛,PE,液化石油氣,二甲醚,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,變壓器油溶解氣,醫(yī)療器械,環(huán)氧乙烷,氯乙酸,氯乙烯,氯乙酰氯,三甲胺,乙胺,

在線留言

主題 *
內(nèi)容 *
公司名
聯(lián)系人 *
聯(lián)系電話 *
電子郵箱
QQ
阿里旺旺
驗證問題 * 1+4等于多少?答案:5
 
儀器交易網(wǎng)
8
推薦收藏該企業(yè)網(wǎng)站